Monitoreo y análisis de falla a ventilador Kuhnle, Koop & Klaus (KKK).
Loading...
Date
2026
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
Universidad de Concepción
Abstract
En este proyecto se analiza, mediante diversas técnicas de ensayos no destructivos (END) y metodologías de mantenimiento, la falla y posterior reparación del rodete de un ventilador centrífugo de la marca Kuhnle, Kopp & Kausch (KKK), perteneciente a la Siderúrgica Huachipato, específicamente al área de Acería Conox. Este equipo es crítico para el proceso de refinación, debido a que se encarga de extraer el material particulado y los gases generados durante la etapa de soplado. Durante su operación, el rotor se encuentra expuesto constantemente a la acumulación de impurezas y al desgaste, condiciones que pueden generar alteraciones en su comportamiento vibracional, las cuales son detectadas mediante un sistema de monitoreo continuo online.
La metodología desarrollada consideró la recopilación y el análisis del historial del equipo, incluyendo datos operacionales, registros de señales vibratorias y antecedentes de fallas típicas asociadas a ventiladores centrífugos. Posteriormente, el equipo fue sometido a un peritaje técnico en las instalaciones de la empresa Turbomecánica, utilizando diversas técnicas de ensayos no destructivos, tales como la inspección visual, partículas magnetizables, ultrasonido y tintas penetrantes. La aplicación de estas técnicas tuvo como objetivo determinar la causa raíz del incremento vibracional, identificar indicaciones relevantes, evaluar el estado estructural del rodete y verificar la efectividad de las reparaciones mediante mediciones vibratorias realizadas en terreno posterior al montaje del equipo.
En un corto periodo de operación, el equipo presentó un comportamiento vibracional anómalo detectado por el sistema de monitoreo online, lo que activó los protocolos de inspección y análisis en terreno. Los resultados iniciales indicaron un comportamiento semejante a una condición de desbalanceo, por lo que se realizaron trabajos de balanceo, alineamiento preventivo y lavado del rotor. Sin embargo, como no se obtuvieron resultados satisfactorios y las altas vibraciones se mantuvieron, se decidió retirar el equipo y realizar un estudio detallado para determinar el origen de la falla.
El peritaje técnico permitió identificar, mediante la inspección visual y los ensayos con tintas penetrantes, un juego excesivo entre el cono de sujeción y el anillo del eje. Esta condición permitió el ingreso de agua y partículas provenientes del proceso de soplado, generando una acumulación de barro metálico de aproximadamente 12 kg, lo que impedía lograr un balanceo adecuado del rotor en terreno. Además, y de manera paralela, se detectó una grieta pasante abierta en la unión entre el disco principal y el eje, junto con grietas transversales asociadas a sobreesfuerzos en la primera línea de perforaciones destinadas al montaje de los pernos de fijación. Todas estas indicaciones fueron intervenidas mediante procedimientos de reparación adecuados y normalizados.
A partir del análisis de falla, se establecieron los procedimientos de reparación del rodete. Para la grieta pasante, la solución aplicada consistió en un recape mediante la técnica de soldadura de paso peregrino. Este procedimiento fue viable debido a que el material presentó buena soldabilidad y una composición química similar a la de un acero SAE 1020. En el caso de las grietas ubicadas en las perforaciones, la reparación se realizó mediante perforaciones en sus extremos, evitando su propagación y reduciendo la concentración de tensiones. Una vez finalizado el montaje del ventilador, las mediciones vibratorias confirmaron que los parámetros de operación se encontraban dentro de los rangos aceptables.
Con el objetivo de determinar la causa raíz del evento, también se realizó un análisis de la estructura soportante del ventilador, compuesta por resortes y amortiguadores. La inspección evidenció la acumulación de aproximadamente 7 toneladas de material endurecido dentro del bastidor. Además, se constató que, durante el montaje, los amortiguadores no habían sido instalados en sus posiciones correctas, y que algunos presentaban una desviación cercana a 300 mm. El mal funcionamiento y el bloqueo del sistema de resortes y amortiguadores impedían la correcta absorción de energía y el adecuado amortiguamiento de las vibraciones, lo que generaba condiciones capaces de provocar fallas severas o catastróficas en el equipo.
This study presents the failure investigation and repair process of the impeller of a KKK (Kuhnle, Kopp & Kausch) centrifugal fan impeller located in the Conox steelmaking area of Siderúrgica Huachipato. This fan is a critical component of the refining process, as it removes particulate matter and processes generated during the blowing stage. Undersevere operating conditions, the rotor is continuously exposed to metallic particle deposition, contamination, and mechanical wear, which can affect its dynamic behavior and generate abnormal vibration responses detected by the online monitoring system. The methodology was based on the analysis of the equipment’s historical data, including operating conditions, vibration trends, and typical failure modes associated with centrifugal fans. A technical inspection was then performed at Turbomecánica using several non-destructive testing (NDT) methods, including visual inspection, magnetic particle testing, ultrasonic testing, and liquid penetrant testing. These techniques were used to identify the cause of the vibration problem, assess the structural integrity of the impeller, and confirm the effectiveness of the repairs through vibration measurements performed after the equipment had been reinstalled. During operation, the fan developed an abnormal vibration pattern within a short period of time, leading to field inspections and further analysis. The initial diagnosis indicated a possible unbalance condition, and corrective actions such as rotor balancing, cleaning, and preventive alignment were carried out. However, the vibration problem persisted after these interventions, suggesting that the unbalance was caused by a deeper failure mechanism. Therefore, the equipment was removed and subjected to a detailed failure analysis. Based on the failure analysis, a repair procedure was developed for the impeller. The through-crack was repaired using a back-step welding technique (known locally as the “paso peregrino” method), which was possible due to the weldability of the material and its chemical composition being similar to that of 53SAE 1020 steel. The cracks around the bolt holes were repaired by drilling relief holes at the crack tips to prevent further propagation and reduce stress concentration. After the repair and subsequent reassembly of the fan, vibration measurements confirmed that the equipment was operating within acceptable parameters. To further determine the root cause of the failure, an evaluation of the supporting structure, composed of springs and dampers, was performed. The inspection identified an accumulation of approximately 7 tons of hardened material inside the support frame. Additionally, several dampers were found to have been incorrectly positioned during assembly, with deviations reaching approximately 300 mm. The restricted movement and malfunction of the damping system reduced the structure’s ability to absorb vibration energy, increasing the dynamic loads on the equipment and contributing to conditions that could lead to severe mechanical failure.
This study presents the failure investigation and repair process of the impeller of a KKK (Kuhnle, Kopp & Kausch) centrifugal fan impeller located in the Conox steelmaking area of Siderúrgica Huachipato. This fan is a critical component of the refining process, as it removes particulate matter and processes generated during the blowing stage. Undersevere operating conditions, the rotor is continuously exposed to metallic particle deposition, contamination, and mechanical wear, which can affect its dynamic behavior and generate abnormal vibration responses detected by the online monitoring system. The methodology was based on the analysis of the equipment’s historical data, including operating conditions, vibration trends, and typical failure modes associated with centrifugal fans. A technical inspection was then performed at Turbomecánica using several non-destructive testing (NDT) methods, including visual inspection, magnetic particle testing, ultrasonic testing, and liquid penetrant testing. These techniques were used to identify the cause of the vibration problem, assess the structural integrity of the impeller, and confirm the effectiveness of the repairs through vibration measurements performed after the equipment had been reinstalled. During operation, the fan developed an abnormal vibration pattern within a short period of time, leading to field inspections and further analysis. The initial diagnosis indicated a possible unbalance condition, and corrective actions such as rotor balancing, cleaning, and preventive alignment were carried out. However, the vibration problem persisted after these interventions, suggesting that the unbalance was caused by a deeper failure mechanism. Therefore, the equipment was removed and subjected to a detailed failure analysis. Based on the failure analysis, a repair procedure was developed for the impeller. The through-crack was repaired using a back-step welding technique (known locally as the “paso peregrino” method), which was possible due to the weldability of the material and its chemical composition being similar to that of 53SAE 1020 steel. The cracks around the bolt holes were repaired by drilling relief holes at the crack tips to prevent further propagation and reduce stress concentration. After the repair and subsequent reassembly of the fan, vibration measurements confirmed that the equipment was operating within acceptable parameters. To further determine the root cause of the failure, an evaluation of the supporting structure, composed of springs and dampers, was performed. The inspection identified an accumulation of approximately 7 tons of hardened material inside the support frame. Additionally, several dampers were found to have been incorrectly positioned during assembly, with deviations reaching approximately 300 mm. The restricted movement and malfunction of the damping system reduced the structure’s ability to absorb vibration energy, increasing the dynamic loads on the equipment and contributing to conditions that could lead to severe mechanical failure.
Description
Tesis presentada para optar al título de Ingeniero/a Civil Mecánico/a.
Keywords
Ventiladores, Pruebas no destructivas, Mantenimiento, Reparaciones