Compuerta de doble persiana para el control del flujo en canales artificiales.

dc.contributor.advisorLink Lazo, Óscar Eduardoes
dc.contributor.authorNicolás, Gatica Ruizes
dc.date.accessioned2022-01-05T17:38:37Z
dc.date.accessioned2024-08-28T20:08:37Z
dc.date.available2022-01-05T17:38:37Z
dc.date.available2024-08-28T20:08:37Z
dc.date.issued2021
dc.descriptionTesis presentada para optar al grado de Magíster en Ciencias de la Ingeniería con mención en Ingeniería Civil.es
dc.description.abstractThe downstream border condition of an open channel, subcritical flow in a laboratory flume is typically materialized through a gate, which imposes a gradually varied conditions upstream. A number of different gates are used for flow control, but the flow alteration they produce in most cases is unknown. In this paper, we analyze the effects of a double louver gate on the upstream flow in a laboratory flume. The flow properties are measured through a particle image velocimetry. Vertical velocity profiles, recirculation zones, and turbulent kinetic energy distributions are analyzed. Results show that the double louver gate is less flow-altering than the common vertical sluice gate, being best suited for the outflow control in flumes, as it conserves parallel streamlines, with a minimum deformation of the vertical velocity profiles, avoiding the formation of recirculation zones and concentrations of turbulent kinetic energy. The double-louver gate is recommended for its implementation in hydraulic laboratories.en
dc.description.campusConcepciónes
dc.description.departamentoDepartamento de Ingeniería Civiles
dc.description.facultadFacultad de Ingenieríaes
dc.identifier.urihttps://repositorio.udec.cl/handle/11594/9321
dc.language.isoeses
dc.publisherUniversidad de Concepciónes
dc.rightsCC BY-NC-ND 4.0 DEED Attribution-NonCommercial-NoDerivs 4.0 Internationalen
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/
dc.subjectCompuertas (Hidráulica)es
dc.subjectHidrodinámicaes
dc.subjectTensión Superficiales
dc.subjectAgua Limpia y Saneamientoes
dc.titleCompuerta de doble persiana para el control del flujo en canales artificiales.es
dc.title.alternativeDouble-louver gate for flow control in flumes = Compuerta de doble persiana para el control del flujo en canales artificiales.en
dc.typeTesises

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
TESIS DOUBLE LOUVER GATE FOR FLOW CONTROL .pdf
Size:
1 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Plain Text
Description:

Collections